High-accuracy measurement solutions for ground resistance and network parameters without power failure.
Advanced diagnostic tools for critical electrical infrastructure and circuit protection validation.
◆ Maintaining power system stability requires precise verification of the earth net. When considering how to test an electrical circuit breaker and its associated grounding, traditional high-current methods often introduce frequency interference and require cumbersome equipment. Our solutions employ digital signal processing to avoid 50Hz interference, enabling measurements without power failure.
◆ By utilizing a variable frequency AC power supply, the Grounding Connection Device Parameter Tester significantly reduces instrument weight while increasing measurement precision. For engineers wondering how to test an electrical circuit breaker network's integrity, this system provides comprehensive data on touch potential, step potential, and soil resistivity.
Integrated design focusing on signal purity, operational mobility, and data integrity.
Advanced interference rejection for high-fidelity readings in active environments.
Streamlined workflows to reduce technician workload and testing downtime.
Lightweight hardware paired with extensive memory for field applications.
Comparative evaluation of testing methodologies and system reliability factors.
Detailed operational limits and measurement capabilities of the Grounding Tester.
| Parameter | Detail / Range | Accuracy/Res | Conditions | Limit/Rating | Unit |
|---|---|---|---|---|---|
| Measurement Range | 0 - 100 | 1 | Standard Mesh | ±(1%±5mΩ) | Ω / mΩ |
| Output Current | 0 - 50 | RMS | Max Output | High Current | A |
| Output Voltage | 0 - 400 | RMS | Variable | Peak | V |
| Power Supply | 380V ±10% | 3-Phase | 47-63Hz | 30KVA | V / Hz |
| Testing Frequency | 42 - 58 | Multi-Freq | Inter-frequency | Stabilized | Hz |
| Anti-Jamming | 1:50 | Signal Ratio | Steady | Accurate | Ratio |
| Working Temp | -20 to 50 | Range | Humidity ≤90% | Environment | °C / RH |
| Physical Dim | 613×488×234 | Size | Weight 39Kg | Portable | mm / Kg |
Proven performance across diverse industries.
A regional substation required precise ground mesh impedance verification without interrupting power to the local community.
The facility needed a comprehensive analysis of step and touch potentials to ensure operator safety during fault conditions.
Deployment of portable testing equipment to verify lightning rod grounding resistance in a remote, high-interference area.
Rapid testing of 1000+ individual grounding points for a new commercial installation using built-in memory.
Tailored solutions for demanding environments.
Verification of substation grounding grids to ensure system stability and fault current dissipation.
Measuring touch and step potentials in hydrothermal and thermal plants for operator protection.
Ground resistance testing for microwave stations and tower sites to prevent equipment damage from lightning.
Accurate testing of lightning rod systems for commercial and industrial buildings to meet safety codes.
Determining soil resistivity for optimized grounding network design in new construction projects.
EMI/EMC grounding validation for sensitive electronic control systems and robotic assembly lines.
Rigorous testing of the variable frequency AC power supply to ensure output stability within 1% tolerance.
Every unit is tested against simulated high-interference environments to validate the DSP rejection capabilities.
Comparative analysis against reference standards to ensure mΩ level accuracy before shipment.
Engineering standards aligned with international power system measurement guidelines.
Expert answers to common technical and commercial inquiries.
It uses a combination of a variable frequency AC power supply and digital signal processing (DSP). This allows the system to shift the test frequency away from the 50Hz grid frequency and filter out clutter, ensuring high accuracy without requiring a power outage.
The system accurately measures ground impedance, ground resistance, voltage gradient, touch potential, step potential, and soil resistivity, covering all conventional ground-network parameters.
Yes, thanks to the interfrequency power supply design, the instrument can perform measurements without power failure, significantly reducing testing downtime and complexity.
Data can be saved in the built-in memory (up to 1000 sets), printed immediately via the thermal printer, or analyzed using the upper computer software with saved voltage and current waveforms.
The device offers a measurement accuracy of ±(1%±5mΩ) with a resolution of 1mΩ, making it ideal for substation ground grids with very low impedance.
Yes, the software can be easily upgraded using a USB flash drive, ensuring your equipment remains current with the latest measurement algorithms.
Get a professional consultation for your grounding and circuit breaker testing requirements.
If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.