Ensure electrical safety through systematic circuit breaker testing and precision dissipation factor measurement for industrial power systems.
Whether performing basic residential maintenance or professional industrial diagnostics, the accuracy of electrical testing defines the safety and longevity of the power system.
Using variable frequency methods and digital filtering to remove power frequency interference, ensuring precise dissipation factor and capacitance readings.
Dual cable connection options supporting both grounded and ungrounded test objects, catering to diverse industrial environments.
Internal memory for 100 results, USB data transfer, built-in thermal printing, and Bluetooth connectivity for wireless tablet operation.
The system automatically handles boosting, measurement, stepping down, and calculations, reducing human error during the test cycle.
Continuous monitoring of voltage output ensures that the output remains stable throughout the testing process for consistent results.
Wireless internet operation via tablet PC allows technicians to monitor tests from a safe distance, improving overall operational security.
| Parameter Item | Value / Range | Accuracy | Resolution | Frequency | Max Current |
|---|---|---|---|---|---|
| Voltage Output Range | 100 - 10000V AC | ±1% U | N/A | 45 – 65Hz | 200mA AC |
| tgδ (Dissipation Factor) Range | 0 - 0.1 | ±1% rdg ±0.0004 | 0.0001 | N/A | N/A |
| Capacitance (Internal 10KV) | 3pF - 60000pF | ± 1% rdg ± 1pF | 0.1pF | N/A | N/A |
| Capacitance (Internal 500V) | 60pF - 1.2μF | ± 1% rdg ± 1pF | 0.1pF | N/A | N/A |
| External Capacitor Range (10KV) | 3pF - 1.5μF | ± 1% rdg ± 1pF | 0.1pF | N/A | N/A |
| Testing Current Range | 10μA - 5A AC | N/A | N/A | N/A | 5A AC |
| Working Environment | -20°C to 50°C | Humidity ≤90%RH | N/A | N/A | N/A |
| Physical Dimensions | 558×357×300mm | Weight: 29kg | N/A | N/A | N/A |
Challenge: High power frequency interference. Solution: Implemented variable frequency digital filtering. Outcome: Precise dissipation factor measurement achieved.
Challenge: Testing both grounded and ungrounded cables. Solution: Used dual cable connection methods. Outcome: Versatile testing capability for all cable types.
Challenge: Field data logging efficiency. Solution: Bluetooth integration with tablet PC. Outcome: Real-time wireless data recording and safety increase.
Challenge: Rapid batch testing. Solution: Automated boosting and calculation workflow. Outcome: Significant reduction in per-unit testing time.
Challenge: Reporting accuracy. Solution: Built-in thermal printer for instant results. Outcome: Elimination of manual transcription errors in reports.
Challenge: Requirement for external power supply. Solution: External high-voltage power supply compatibility. Outcome: Enhanced testing range for oversized objects.
Measuring dissipation factor to evaluate the aging state of transformer insulation and prevent catastrophic failure.
Performing tan delta tests on high-voltage cables to identify water ingress or chemical degradation in the sheath.
Validating the dielectric properties of switchgear components to ensure they can handle rated transient voltages.
Using high-precision capacitance measurement to detect failing units in power factor correction banks.
Scheduling periodic tan delta tests to identify trending degradation before it leads to a blackout.
Standardized validation of high-voltage electrical components using certified standard capacitors.
Every unit is tested against high-voltage standard capacitors to ensure the ±1% voltage and tgδ accuracy.
Advanced digital filtering is applied to eliminate power frequency interference, critical for low-value dissipation measurements.
All devices are built with thermal protection and high-voltage stability monitoring to protect the operator and the test object.
For residential use, you can use the built-in test button on AFCI/GFCI breakers or a multimeter to check continuity and voltage. For advanced insulation analysis in industrial systems, a tan delta tester is required to check for dielectric loss.
It measures the dissipation factor of insulation. An increase in tgδ typically indicates moisture, contamination, or aging, allowing for predictive maintenance of high-voltage equipment.
Yes, the system is designed to support external high voltage power supplies and standard capacitors for testing objects that exceed the internal range.
It eliminates power frequency interference from the surrounding environment, allowing the tester to capture very small dissipation factors with high accuracy.
Bluetooth allows the technician to operate the tester via a tablet PC from a safe distance, which is essential when working with high-voltage equipment.
Results can be saved in the internal memory (up to 100 entries), transferred via USB flash disk, or printed immediately using the built-in thermal printer.
Contact our technical team to discuss your insulation testing requirements or request a formal quote for the CDF8200A Tan Delta Tester.