PRECISION ELECTRICAL
Transmission Line Analysis for EHV Systems

Advanced LPT15 Series Analyzers for high-voltage transmission line parameters, ensuring grid stability through variable frequency measurement technology.

5000+
Units Produced
120+
Regions Served
7 Days
Sample Lead Time
98.5%
On-Time Delivery

Advanced Parameter Measurement
& Engineering Analysis

Optimizing Power System Modelling through High-Accuracy Impedance and Resistance Testing

◆ In the context of long-distance extreme-high-voltage (EHV) and ultra-high-voltage (UHV) lines, accurate power-frequency parameter measurement is critical. However, users often face challenges with what is the blue test button on a circuit breaker and overall system verification. The HANY LPT15 series analyzer solves these issues using variable frequency technology to measure positive and zero sequence impedance with extreme precision.

◆ From an engineering perspective, the all-in-one electronic design removes the need for bulky traditional transformers. By integrating what is the blue test button on a circuit breaker operational logic with advanced Fourier Transformation, the LPT15 ensures that measurements are immune to strong external interference and induction currents up to 100A.

Core Engineering
Technological Pillars

The integration of signal processing and power electronics for maximum field reliability.

01

Signal Processing Accuracy

Utilizing digital filtering to ensure results remain consistent regardless of environmental noise.

▸Fourier Transformation: Converts time-domain signals to frequency-domain for precise analysis.
▸Digital Filtering: Eliminates harmonic interference and external electrical noise.
▸Variable Frequency: Enables accurate measurement of reactance-dominated lines.
02

Hardware Integration

All-in-one electronic design replacing traditional heavy transformers for field portability.

▸Absorption Feedback: Withstands 10-100A induction current without suppression gear.
▸Three-Phase Parallel: Triple induction current capability for zero-order impedance.
▸All-Electronic Design: Compact size and light weight compared to traditional inverters.
03

Operational Efficiency

Optimized workflow for rapid field testing and data acquisition.

▸Bluetooth Control: Remote operation via mobile/pad for increased safety.
▸Single-Connection Test: Complete phase, DC resistance, and parameters in one setup.
▸Auto-Calculation: Automated boosting, measuring, and lowdown voltage sequences.

Technical Analysis
& Reference Metrics

Relative performance and application distribution based on typical deployment data.

Application Distribution

Relative Performance Evaluation

Technical Specification
Data Sheet

Precise parameters for the LPT15 series power frequency transmission line analyzer.

Parameter Range/Value Resolution Accuracy Condition Unit
Capacitance Range 0.1~30 0.01 ±(1%C+0.01μF) 1~50μF μF
Resistance Range 0.5~400 0.01 ±(1%Z+0.01Ω) 1~400Ω Ω
Impedance Angle 0~360 0.01 ±0.3° Standard deg
DC Resistance 0.02~60 0.1mΩ ±(0.2%R+0.2mΩ) 2A-4A Output Ω
Voltage Range 10~750 N/A ±(0.5%U+0.2V) Max 750V V
Current Range 0.5~20 N/A ±(0.5%I+0.02A) Standard A
Induction Voltage <30 N/A Standing kV N/A
Test Frequency 42~58 N/A Range Standard Hz

Real-World
Impact

Proven performance across diverse industries.

Regional Power Grid

UHV Transmission Line

Client required precise measurement of positive sequence impedance for a new 1000kV line under high external interference.

Measurement Accuracy:High
Testing Time:Reduced

Industrial Complex

Underground Cable Network

Installation of the LPT15 analyzer to check line phases and DC resistance for a high-capacity industrial park.

Phase Verification: Validated
Setup Effort: Simplified

Cross-Border Interconnector

Extreme Environment Testing

Operating the LPT15 in T:-20 to 50°C conditions to measure zero-sequence open circuit impedance of intercontinental lines.

Temp Stability: Confirmed
Interference: Suppressed

Urban Substation Upgrade

Compact Space Deployment

Replaced traditional bulky transformers with the LPT15 for faster commission of a city-center power hub.

Portability: High
Reduced Setup Time

Industry
Applications

Tailored solutions for demanding environments.

EHV TRANSMISSION

Measuring power-frequency parameters for extreme-high-voltage lines to ensure stability in long-distance transmission.

UHV POWER GRIDS

Specialized testing for ultra-high-voltage networks where reactance dominance makes traditional measurement difficult.

CABLE NETWORK AUDIT

Performing comprehensive phase checks and DC resistance measurements for industrial cable systems.

SUBSTATION COMMISSING

Rapid validation of coupling inductors and capacitors during the commissioning phase of power hubs.

GRID MAINTENANCE

Regular monitoring of transmission line parameters to prevent failures and optimize power flow modelling.

ENERGY INFRASTRUCTURE

Deployment in large-scale energy projects requiring high-precision zero-sequence impedance data.

Quality Assurance
& Export Standards

◈ Signal Integrity Verification

Every analyzer undergoes rigorous Fourier Transformation accuracy tests to ensure zero-drift in variable frequency modes.

◈ High-Voltage Stress Testing

Units are tested against induction currents up to 100A to verify the absorption feedback circuit's effectiveness.

◈ Environmental Calibration

Full-spectrum calibration across -20°C to 50°C to ensure field reliability in extreme climates.

Trust Verified

Committed to delivering precise electrical instrumentation for critical power infrastructure.

✓ Precision Calibrated
✓ Field-Tested Stability
✓ Industrial Grade Design

Frequently Asked
Questions

Expert answers to common technical and commercial inquiries.

01

What is the primary use of the LPT15 Transmission Line Analyzer?

The LPT15 is designed for measuring power-frequency parameters of EHV and UHV transmission lines, specifically positive/zero sequence impedance and DC resistance, to facilitate accurate power system modelling.

02

How does the variable frequency method improve measurement accuracy?

By using variable frequency and Fourier Transformation, the analyzer can isolate the desired parameters from reactance-dominated signals and eliminate the impact of external interference common in UHV environments.

03

Can the analyzer withstand high induction currents?

Yes, the unique absorption feedback circuit allows the tester to withstand induction currents from 10A to 100A without requiring an external anti-jamming suppression device.

04

What are the advantages of the all-in-one electronic design?

It significantly reduces the weight and size of the instrument compared to traditional inverter/frequency transformer structures, making it highly portable for remote field operations.

05

Does it support remote operation?

Yes, an optional built-in Bluetooth module allows engineers to operate the analyzer via mobile phones or tablets, improving operator safety by maintaining distance from high-voltage equipment.

06

How is test data managed and exported?

Data is displayed on an LCD screen, stored in a large-capacity memory (up to 1024 sets), and can be transferred via USB drive for computer analysis or printed directly via the high-speed thermal printer.

Secure Your Grid Analysis Tools

Contact our engineering team today for a technical consultation and a tailored quote for the LPT15 Series.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.